Electrical characteristics
- Contact current rating: A current of DC 1.25A max. shall be applied collectively to A1,A4,A9,A12,B1,B4,B5,B9,B12,and DC 0.25A shall be applied collectively to other contacts.
- Contact resistance: 40 Milliohms (MAX) initial for VBUS, GND and all other contacts. Maximum change (delta) of +10 Milliohms after environmental stresses.
- Dielectric withstanding voltage : 100 V AC MIN (RMS). Insulation resistance: 100 MEGOHMS MIN.
Mechanical characteristics
- Connector insertion force: 5~20N at a maximum rate of 12.5mm per minute.
- Connector extraction force: 8~20N up to 1000 mating cycles, and 6~20N after the specified insertion/extration or durability cycles at a maximum rate of 12.5mm per minute.
- Durability: 10000 cycles minimum. Operating temperature: -55°C TO +85°C.
- The connector is Rohs compliant and halogen free compliant.